Our facade and window systems are placed on the market with CE marking to harmonised standards under the Construction Products Regulation: TS EN 13830 for curtain walling and TS EN 14351-1 for windows and external doors.
Performance tests
| Property | Test standard | Classification |
|---|---|---|
| Air permeability | EN 12153 | EN 12152 (AE) |
| Watertightness (static) | EN 12155 | EN 12154 (R7 – RE1200) |
| Wind load resistance | EN 12179 | EN 13116 |
| Impact resistance | EN 14019 | I4 / E4 |
Mock-up testing
On high-rise and bespoke projects we build a typical section of the facade at full scale and put it through air, water, wind and dynamic water tests at an accredited laboratory. The architect and client representatives attend, and the results feed into the design before fabrication.
Management systems
- ISO 9001:2015 Quality Management
- ISO 14001:2015 Environmental Management
- ISO 45001:2018 Occupational Health and Safety Management
Material traceability
Batch numbers of profiles, glass, silicone and anchors are recorded for every panel. For structural glazing, butterfly and peel tests are carried out every shift, and the results are kept in the project file.